Split-Bolus Multidetector-Row Computed Tomography Technique for Characterization of Focal Liver Lesions in Oncologic
Michele Scialpi1, Luisa Pierotti1, Sabrina Gravante1
1Department of Surgical and Biomedical Sciences, Division of Radiology 2, Perugia University, S. Maria Della Misericordia Hospital, Perugia, Italy.
Background:
In oncologic patients, the liver is the most common target for metastases. An accurate detection and characterization of focal liver lesions in patients with known primary extrahepatic malignancy are essential to define management and prognosis.
Objectives:
To assess the diagnostic accuracy of the split-bolus multidetector-row computed tomography (MDCT) protocol in the characterization of focal liver lesions in oncologic patients.
Patients And Methods:
We retrospectively analyzed the follow-up split-bolus 64-detector row CT protocol in 36 oncologic patients to characterize focal liver lesions. The split-bolus MDCT protocol by intravenous injection of two boluses of contrast medium combines the hepatic arterial phase (HAP) and hepatic enhancement during the portal venous phase (PVP) in a single-pass.
Results:
The split-bolus MDCT protocol detected 208 lesions and characterized 186 (89.4%) of them: typical hemangiomas (n = 9), atypical hemangiomas (n = 3), cysts (n = 78), hypovascular (n = 93) and hypervascular (n = 3) metastases. Twenty two (10.6%) hypodense lesions were categorized as indeterminate (≤5 mm). The mean radiation dose was 24.5±6.5 millisieverts (mSv).
Conclusion:
The designed split-bolus MDCT technique can be proposed alternatively to triphasic MDCT and in a single-pass to PVP in the initial staging and in the follow-up respectively in oncologic patients.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...