Related Experiment Video
Updated: Mar 14, 2026

The Combination of Transcranial Alternating Current Stimulation and Electroencephalogram
Published on: October 10, 2025
Monophasic ß-TCP vs. biphasic HA/ß-TCP in two-stage sinus floor augmentation procedures - a prospective randomized
Damir Jelusic1, Matthias L Zirk2, Tim Fienitz2
1Private Practice, Opatja, Croatia.
Objectives:
To compare a monophasic (100% ß-TCP) and a biphasic (60% HA and 40% ß-TCP) bone substitute material (BSM) regarding biocompatibility, osteoconductivity and implant stability using histological, radiological and resonance frequency analysis.
Material And Methods:
Sixty-seven sinus floor elevations were performed in 60 patients. One patient group (monophasic bone substitute [MBS], 30 patients, 32 sinuses) was augmented by the use of the monophasic material (Bioresorb® , Sybron Implant Solutions, Bremen, Germany), while the second group (biphasic bone substitute (BBS), 30 patients, 35 sinuses) received a biphasic material (Maxresorb® , Botiss Biomaterials, Berlin, Germany). Cone beam CT images were taken immediately after augmentation and prior to implant placement after 6 months. Trephines were harvested, while the implant bed was prepared. Resonance frequency analysis was performed immediately after implant placement and 6 months later. Descriptive analysis was performed on all augmented sinus (n = 67). For statistical comparison of the groups, one sinus of each bilaterally treated patient was randomly excluded, resulting in 30 sinuses grafted with MBS and 30 sinuses grafted with BBS (n = 60).
Results:
Histomorphometrical analysis of all sinuses displayed comparable results for both groups regarding new bone matrix (MBS 36.16 ± 19.37%, BBS 38.42 ± 12.61%), residual BSM (MBS 30.26 ± 11.7%, BBS 32.66 ± 12.57%) and non-mineralized tissue (MBS 34.29 ± 18.32%, BBS 28.92 ± 15.04) %) (P > 0.05, respectively). Radiological volume of BBS was significantly more stable (volume loss of 22.2% for MBS, 6.66% for BBS; P < 0.001), and homogeneity of the graft after 6 months was higher for BBS than that for MBS (P < 0.05). Resonance frequency analysis endorsed a higher implant stability quotient for BBS after 6 months than that for MBS (MBS 78.31 ± 5.81, BBS 80.42 ± 6.31; P < 0.05, Mann-Whitney U-test, respectively).
Conclusion:
Both monophasic and biphasic materials show good biocompatibility and osteoconductivity with satisfactory support on implant stability. BBS remains more stable in terms of volume maintenance and radiological graft homogeneity after a healing period of 6 months.
More Related Videos
06:51Concurrent Electroencephalography Recording During Transcranial Alternating Current Stimulation tACS
Published on: January 22, 2016
07:52Author Spotlight: Advancing Human Brain Modulation – Optimized Protocols for Transcranial Ultrasound Stimulation Experiments
Published on: June 28, 2024