Photoplethysmographic waveform characteristics of newborns with coarctation of the aorta
L Palmeri1,2, G Gradwohl3, M Nitzan3
1Department of Pediatrics, Cohen Children's Medical Center of New York/Northwell Health System, New Hyde Park, NY, USA.
Objective:
Fetal echocardiography, physical examination and pulse oximetry detect only half of coarctation of aorta (CoA) cases. We aimed to quantify delayed arrival and diminished amplitude of lower extremity photoplethysmographic (PPG) pulses relative to the right hand in affected patients.
Study Design:
We studied 8 CoA infants and 32 healthy controls. The pulse arrival time difference between foot and hand (f-hTD) and pulse amplitude ratio (F/H) were measured on PPG signal waveforms by digitally-determining maxima and minima of systolic decrease of light transmission. Mann-Whitney test was used for group comparisons.
Results:
In comparison to healthy newborns, CoA infants' PPG waveforms demonstrated prolonged f-hTD (mean±s.d. of 73.2±26.6 versus 35.2±8.3 ms, P<0.001) and lower F/H (0.57±0.26 versus 0.99±0.58, P=0.014).
Conclusions:
F-hTD and F/H are quantifiable from hand- and foot-derived PPG waveforms and are significantly different in CoA versus healthy newborns. Larger studies are needed to validate PPG for improved critical congenital heart disease screening.
More Related Videos
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Aortic Regurgitation I: Introduction
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...