Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Peri-implant soft tissue analyses comparing Ti and ZrO2 abutments: an animal study on beagle dogs
Juan Blanco1, Leticia Caneiro2, Antonio Liñares2
1Department of Estomatology, University of Santiago de Compostela, Santiago de Compostela, Spain. jblanco@blancoramos.net.
Objective:
The aim of this study was to evaluate the soft tissue histomorphometric composition around implant abutments comparing two different materials, titanium (Ti) and zirconia (ZrO2 ).
Material And Methods:
Twelve implants were placed at bone level in the mandible of six beagle dogs (one in each side). At the same day of surgery one titanium abutment was screwed to the implant in one side (control group) and a zirconia abutment was screwed in the contralateral side. Nine months after implant/abutments placement, animals were sacrificed for histological analysis. Descriptive analysis was calculated for each variable and Wilcoxon test was applied to evaluate histomorphometric variables.
Results:
At the end of the study the soft tissue dimension at Ti and ZrO2 were similar in all counterparts: biological width, the length of the barrier epithelium, length of the connective tissue, and the percentage of collagen fibers density. However, the percentage of blood vessels was higher for the Ti in comparison to ZrO2 (5.11% ± 1.70 and 2.23% ± 0.98, respectively [P = 0.016]).
Conclusions:
Peri-implant soft tissue histomorphology composition was similar in implant abutments made of ZrO2 and titanium after 9 months of healing.