Nasal Dilator Strip is an Effective Placebo Intervention for Severe Obstructive Sleep Apnea
Fabiana Yagihara1, Geraldo Lorenzi-Filho1,2, Rogerio Santos-Silva1,2
1Faculdade de Medicina da Universidade de São Paulo, Heart Institute (InCor), Pulmonary Division, Sleep Laboratory, São Paulo, Brazil.
Study Objectives:
The aim of this study was to evaluate the effects of nasal dilator strip (NDS) as a placebo intervention compared with continuous positive airway pressure (CPAP) treatment in patients with severe obstructive sleep apnea (OSA).
Methods:
Patients were treated with both NDS and nasal CPAP. The sequence was randomized and interposed by 15 days of washout. Polysomnography was performed at baseline and on the first night of intervention with NDS and CPAP (titration). The Epworth Sleepiness Scale (ESS), Functional Outcomes of Sleep Questionnaire (FOSQ), and Beck Depression Inventory (BDI) were completed at baseline and at the end of both interventions. A questionnaire on the comfort and satisfaction (0 = no to 10 = total) was completed at the end of each intervention.
Results:
Twenty-six patients with OSA were evaluated (19 male; age 46.3 ± 9.3 y; body mass index 33.2 ± 5.1 kg/m2; ESS 15.8 ± 4.1; apnea-hypopnea index 60.7 ± 25.2). Adherence was high in both NDS (98%) and CPAP interventions (94%; 5.8 ± 1.7 h/night). In contrast to the baseline values, NDS intervention had no significant effect on all polysomnographic parameters, but NDS improved somnolence (ESS 13.0 ± 5.4, p = 0.001) and depressive symptoms (BDI 7.7 ± 6.9, p = 0.005). Reported satisfaction was significantly higher for CPAP than for NDS (sleep quality 9.2 ± 0.8 vs. 6.1 ± 2.1; wake up at morning: 8.6 ± 1.2 vs. 6.0 ± 2.2; daily activities: 8.9 ± 1.4 vs. 5.8 ± 1.5; quality of life: 8.3 ± 2.1 vs. 3.8 ± 3.5, p < 0.001), but similar low levels of difficulty for both interventions were observed (1.3 ± 2.2 vs. 0.3 ± 1.3, p = 0.098).
Conclusions:
Our data indicate that NDS is an attractive placebo intervention for randomized controlled trials evaluating the effects of CPAP in sleepy patients with OSA.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Blind Procedures
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...