Related Experiment Video
Updated: Mar 13, 2026

Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
Illumination Variation-Resistant Video-Based Heart Rate Measurement Using Joint Blind Source Separation and Ensemble
Abstract:
Recent studies have demonstrated that heart rate (HR) could be estimated using video data [e.g., exploring human facial regions of interest (ROIs)] under well-controlled conditions. However, in practice, the pulse signals may be contaminated by motions and illumination variations. In this paper, tackling the illumination variation challenge, we propose an illumination-robust framework using joint blind source separation (JBSS) and ensemble empirical mode decomposition (EEMD) to effectively evaluate HR from webcam videos. The framework takes the hypotheses that both facial ROI and background ROI have similar illumination variations. The background ROI is then considered as a noise reference sensor to denoise the facial signals by using the JBSS technique to extract the underlying illumination variation sources. Further, the reconstructed illumination-resisted green channel of the facial ROI is detrended and decomposed into a number of intrinsic mode functions using EEMD to estimate the HR. Experimental results demonstrated that the proposed framework could estimate HR more accurately than the state-of-the-art methods. The Bland-Altman plots showed that it led to better agreement with HR ground truth with the mean bias 1.15 beats/min (bpm), with 95% limits from -15.43 to 17.73 bpm, and the correlation coefficient 0.53. This study provides a promising solution for realistic noncontact and robust HR measurement applications.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring pulse
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

