Bonding effectiveness of composite-dentin interfaces after mechanical loading with a new device (Rub&Roll).
Anelise Fernandes Montagner1, Niek J Opdam, Jan L Ruben
1Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas.
This study shows that increased mechanical loading on dental adhesives reduces their bond strength to dentin. Self-etch adhesives performed better under high mechanical stress, indicating improved durability.
Area of Science:
- Dental Materials Science
- Biomaterials Engineering
- Adhesive Dentistry
Background:
- Dental restorations require strong adhesion between restorative materials and tooth structure.
- Evaluating the long-term durability of adhesive systems under mechanical stress is crucial for clinical success.
- New devices for simulating intraoral conditions aid in material testing.
Purpose of the Study:
- To assess the impact of a novel mechanical loading device on the microtensile bond strength (µTBS) of two different adhesive systems to dentin.
- To compare the performance of a self-etch and an etch-and-rinse adhesive system under varying mechanical loading conditions.
- To analyze fracture modes and determine the influence of mechanical cycles on bond integrity.
Main Methods:
- Forty human molars were utilized, divided into two adhesive groups: Clearfil SE Bond (self-etch) and Adper Scotchbond 1XT (etch-and-rinse).
- Samples underwent aging through mechanical loading using a new device, with groups subjected to 0 (control), 250,000, 500,000, and 750,000 cycles.
- Microtensile bond strength (µTBS) was measured, and fracture modes were analyzed using Kruskal-Wallis and post hoc tests.
Main Results:
- Both mechanical loading and the type of adhesive system significantly affected µTBS (p<0.001 and p=0.024, respectively).
- Increasing mechanical cycles generally decreased µTBS for both adhesive systems.
- The self-etch adhesive (Clearfil SE Bond) demonstrated significantly higher µTBS compared to the etch-and-rinse system (Adper Scotchbond 1XT) only after 750,000 mechanical cycles.
Conclusions:
- The novel mechanical loading device effectively reduced the bond strength of tested adhesive systems to dentin with increasing cycles.
- Self-etch adhesive systems may offer superior long-term durability under significant mechanical loading compared to etch-and-rinse systems.
- Material differences in bond strength degradation under mechanical stress become apparent only after substantial cyclic loading (750,000 cycles).