Related Experiment Video
Updated: Mar 13, 2026

Amplifying and Quantifying HIV-1 RNA in HIV Infected Individuals with Viral Loads Below the Limit of Detection by Standard Clinical Assays
Published on: September 26, 2011
Detection and quantification of HIV-1 RNA with a fully automated transcription-mediated-amplification assay
Background:
Nucleic acid testing is the major method used to monitor HIV viral load. Commercial systems based on real-time PCR assays are available for high-volume centralized laboratory testing, but they are not fully automated.
Objectives And Study Design:
We have compared the diagnostic performance of the Hologic Aptima HIV-1 Quant Dx assay (Aptima) (based on real-time TMA) on the Panther instrument, a fully-automated random access platform, to that of, the Roche Cobas Ampliprep Cobas TaqMan (CAP/CTM) HIV-1 version 2.0 (based on real-time PCR).
Results:
Probit analysis of replicate dilutions of NIBSC WHO International HIV-1 Standard, gave LODs of 8.6 c/ml for Aptima and 15.2 c/ml for CAP/CTM. The agreement between the assays was excellent when measuring HIV RNA in a calibrated reference (κ=0.90, p<0.001) and good when measuring clinical samples (κ=0.62, p<0.001). The correlation among the samples quantified by the two methods was very good (r=0.95, p<0.001) and the mean difference between the values obtained with the two assays was 0.02 log c/ml for B and non-B subtypes. The vast majority of results showed <0.5 log variance between the two assays (89%); only one sample showed results that differed by over 1.0 log c/ml.
Conclusion:
The performance of the new fully automated Aptima assay is adequate for clinical monitoring of HIV-1 RNA during infections and treatment. The Aptima assay is well suited for routine laboratory use.