Related Experiment Video
Updated: Mar 13, 2026

Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry
Published on: February 4, 2017
Clinical Trial with Sodium 99mTc-Pertechnetate Produced by a Medium-Energy Cyclotron: Biodistribution and Safety
Svetlana V Selivanova1,2, Éric Lavallée3, Helena Senta3
1Sherbrooke Molecular Imaging Center, CRCHUS, Sherbrooke, Quebec, Canada Svetlana.V.Selivanova@USherbrooke.ca.
Abstract:
A single-site prospective open-label clinical study with cyclotron-produced sodium 99mTc-pertechnetate (99mTc-NaTcO4) was performed in patients with indications for a thyroid scan to demonstrate the clinical safety and diagnostic efficacy of the drug and to confirm its equivalence with conventional 99mTc-NaTcO4 eluted from a generator. Methods:99mTc-NaTcO4 was produced from enriched 100Mo (99.815%) with a cyclotron (24 MeV; 2 h of irradiation) or supplied by a commercial manufacturer (bulk vial eluted from a generator). Eleven patients received 325 ± 29 (mean ± SD) MBq of the cyclotron-produced 99mTc-NaTcO4, whereas the age- and sex-matched controls received a comparable amount of the generator-derived tracer. Whole-body and thyroid planar images were obtained for each participant. In addition to the standard-energy window (140.5 keV ± 7.5%), data were acquired in lower-energy (117 keV ± 10%) and higher-energy (170 keV ± 10%) windows. Vital signs and hematologic and biochemical parameters were monitored before and after tracer administration. Results: Cyclotron-produced 99mTc-NaTcO4 showed organ and whole-body distributions identical to those of conventional 99mTc-NaTcO4 and was well tolerated. All images led to a clear final diagnosis. The fact that the number of counts in the higher-energy window was significantly higher for cyclotron-produced 99mTc-NaTcO4 did not influence image quality in the standard-energy window. Image definition in the standard-energy window with cyclotron-produced 99mTc was equivalent to that with generator-eluted 99mTc and had no particular features allowing discrimination between the 99mTc production methods. Conclusion: The systemic distribution, clinical safety, and imaging efficacy of cyclotron-produced 99mTc-NaTcO4 in humans provide supporting evidence for the use of this tracer as an equivalent for generator-eluted 99mTc-NaTcO4 in routine clinical practice.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
07:52In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy
Published on: December 9, 2015
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...