Laboratory performance study for passive sampling of nonpolar chemicals in water
Kees Booij1, Foppe Smedes2,3, Steven Crum4
1NIOZ Royal Netherlands Institute for Sea Research, Texel, The Netherlands.
Abstract:
Two laboratory performance studies with 21 and 11 participants were carried out for passive sampling of nonpolar chemicals in water, using silicone samplers that were deployed for 7 wk and 13 wk at 2 river sites in the Netherlands. Target analytes were polychlorinated biphenyls, polycyclic aromatic hydrocarbons (PAHs), polybrominated diphenyl ethers (PBDEs), hexachlorobutadiene, hexachlorobenzene, and a number of performance reference compounds (PRCs). Calculation of aqueous concentrations based on prescribed input values and a prescribed uptake model was also included. Between-laboratory coefficients of variation (CVs) in the analysis of target compounds were approximately 20% at concentrations of 100 ng g-1 and approximately 100% at concentrations of 0.01 ng g-1 , which was similar to previous results for the analysis of biota samples. The analysis of PRCs yielded water sampling rates with a between-laboratory CV of 18% to 30%. The sampling rate model showed a nearly perfect match with the consensus values of retained PRCs. The implications of the present study for future interlaboratory exercises are discussed. Environ Toxicol Chem 2017;36:1156-1161. © 2016 SETAC.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation