Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Correlative analysis of cement-dentin interfaces using an interfacial fracture toughness and micro-tensile bond
Evelise M Souza1, Jan De Munck2, Pong Pongprueksa2
1KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & University Hospitals Leuven, Dentistry, Leuven, Belgium; Pontifícia Universidade Católica do Paraná (PUCPR), School of Life Sciences, Graduate Program in Dentistry & Federal University of Paraná, Dental School, Restorative Dentistry Department, Curitiba, PR, Brazil.
Objectives:
To determine the interfacial fracture toughness (iFT) and micro-tensile strength (μTBS) of composite cements bonded to dentin.
Methods:
Fifty feldspar ceramic blocks (Vita Mark II, Vita Zahnfabrik) were luted onto dentin using two self-adhesive (G-CEM LinkAce, GC; SpeedCEM, Ivoclar Vivadent), two self-etch (Multilink Primer & Multilink Automix, Ivoclar Vivadent; Scotchbond Universal & RelyX Ultimate, 3 M ESPE), and one etch-and-rinse (Excite F DSC & Variolink II, Ivoclar Vivadent) composite cement (n=10). After 48h in 100% relative humidity at 37°C, one half of each tooth was sectioned in sticks with a chevron notch at the cement-dentin interface and tested in a 4-point bending test setup (iFT). The remaining half of the tooth was sectioned in micro-specimens and stressed in tension until failure (μTBS). The mode of failure was determined with a stereomicroscope at 50× magnification. Data were submitted to Weibull analysis and Pearson's correlation (α=0.05).
Results:
At 10% probability of failure, no significant differences could be found using iFT, while the etch-and-rinse composite cement Variolink II presented a significantly higher μTBS at this level. At 63.2% probability of failure, the self-adhesive composite cement G-CEM LinkAce revealed a significantly lower μTBS and iFT, and the self-etch cement Multilink Automix also revealed a significantly lower μTBS than all other cements. The correlation found between iFT and μTBS was moderate and not significant (r2=0.618, p=0.11).
Significance:
Overall, the etch-and-rinse and 'universal' self-etch composite cements performed best. The micro-tensile bond strength and interfacial fracture toughness tests did not correlate well.
Related Concept Videos
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Microcracking in Concrete
Bonding and Strength of Aggregate
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
Porosity in Cement Paste
The balance of water to cement in the mix is...