Related Experiment Video
Updated: Mar 13, 2026

Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Estimation of breathing rate in thermal imaging videos: a pilot study on healthy human subjects
Carina Barbosa Pereira1, Xinchi Yu2, Michael Czaplik3
1Chair for Medical Information Technology, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany. pereira@hia.rwth-aachen.de.
Abstract:
Diverse studies have demonstrated the importance of monitoring breathing rate (BR). Commonly, changes in BR are one of the earliest and major markers of serious complications/illness. However, it is frequently neglected due to limitations of clinically established measurement techniques, which require attachment of sensors. The employment of adhesive pads or thoracic belts in preterm infants as well as in traumatized or burned patients is an additional paramount issue. The present paper proposes a new robust approach, based on data fusion, to remotely monitor BR using infrared thermography (IRT). The algorithm considers not only temperature modulation around mouth and nostrils but also the movements of both shoulders. The data of these four sensors/regions of interest need to be further fused to reach improved accuracy. To investigate the performance of our approach, two different experiments (phase A: normal breathing, phase B: simulation of breathing disorders) on twelve healthy volunteers were performed. Thoracic effort (piezoplethysmography) was simultaneously acquired to validate our results. Excellent agreements between BR estimated with IRT and gold standard were achieved. While in phase A a mean correlation of 0.98 and a root-mean-square error (RMSE) of 0.28 bpm was reached, in phase B the mean correlation and the RMSE hovered around 0.95 and 3.45 bpm, respectively. The higher RMSE in phase B results predominantly from delays between IRT and gold standard in BR transitions: eupnea/apnea, apnea/tachypnea etc. Moreover, this study also demonstrates the capability of IRT to capture varied breathing disorders, and consecutively, to assess respiratory function. In summary, IRT might be a promising monitoring alternative to the conventional contact-based techniques regarding its performance and remarkable capabilities.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Volumes and Capacities I
Application of Integration: Problem Solving
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:

