Decreased patient exposure to ionizing radiation during interventional rheumatology procedures after optimization of
Céline Cozic1, Fabien Audran2, Christophe Blanchard3
1Service de rhumatologie, CHD Vendée, boulevard Stéphane-Moreau, 85925 La Roche-sur-Yon cedex 9, France.
Objectives:
To decrease radiation exposure of patients undergoing interventional rheumatology procedures, without adversely affecting quality of care.
Methods:
The radiation dose received, assessed by the dose-area product (DAP), was measured during 283 intraarticular injections performed under fluoroscopic guidance between May and July 2013. Then, three steps were taken to decrease patients' radiation exposure: a copper filter was added, the anti-scatter grid was removed, and exposure cell sensitivity was set at the highest value. DAP was measured during 158 intraarticular injections performed in 2014 with these measures in place.
Results:
Mean DAP before optimization was 175μGray·m2 during facet joint injections (n=4) and 43μGray·m2 during hip injections but was less than 20μGray·m2 for injections into the shoulders (15.7μGray·m2), ankles (7.7μGray·m2), wrists (3.7μGray·m2), and fingers (3.3μGray·m2). After optimization, DAP decreased markedly for all injection sites, by 52% (shoulders) to 87% (facet joints, 22.7μGray·m2). Decreases occurred at all three steps of the procedure, i.e., patient installation, injection, and last image hold. Exposure during facet joint injections varied from 84 (54.5-108.5) μGray·m2 when body mass index (BMI) was <25kg/m2 to 228.9 (161.3-340.4)μGray·m2 when BMI was>30kg/m2.
Conclusion:
Simple technical changes translate into large decreases in patient radiation exposure during fluoroscopically-guided injections, particularly at the facet joints and in obese patients.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Rheumatic Heart Disease III: Medical Management
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT