Related Experiment Video
Updated: Mar 12, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Volumetric shrinkage and film thickness of cementation materials for veneers: An in vitro 3D microcomputed tomography
Camila S Sampaio1, João Malta Barbosa2, Eduardo Cáceres3
1Doctoral student, Department of Restorative Dentistry, State University of Campinas, Piracicaba, Brazil; Visiting Scholar, Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY; and Research Professor, Department of Biomaterials, University of Los Andes, Santiago, Chile.
Statement Of Problem:
Few studies have investigated the volumetric polymerization shrinkage and film thickness of the different cementation techniques used to cement veneers.
Purpose:
The purpose of this in vitro study was to evaluate the volumetric polymerization shrinkage (VS) and film thickness (FT) of various cementation techniques through 3-dimensional (3D) microcomputed tomography (μCT).
Material And Methods:
Forty-eight artificial plastic maxillary central incisors with standard preparations for veneers were provided by a mannequin manufacturer (P-Oclusal) and used as testing models with the manufacturer's plastic veneers. They were divided into 8 groups (n=6): RelyX Veneer + Scotchbond Universal (RV+SBU); Variolink Esthetic LC+Adhese Universal (VE+ADU); Filtek Supreme Ultra Flowable + Scotchbond Universal (FF+SBU); IPS Empress Direct Flow + Adhese Universal (IEF+ADU); Filtek Supreme Ultra Universal + Scotchbond Universal (FS+SBU); IPS Empress Direct + Adhese Universal (IED+ADU); Preheated Filtek Supreme Ultra Universal + Scotchbond Universal (PHF+SBU); and Preheated IPS Empress Direct + Adhese Universal (PHI+ADU). Specimens were scanned before and after polymerization using a μCT apparatus (mCT 40; Scanco Medical AG), and the resulting files were imported and analyzed with 3D rendering software to calculate the VS and FT. Collected data from both the VS and FT were submitted to 1-way ANOVA (α=.05).
Results:
VE+ADU had the lowest volumetric shrinkage (1.03%), which was not significantly different from RV+SBU, FF+SBU or IEF+ADU (P>.05). The highest volumetric shrinkage was observed for FS+SBU (2.44%), which was not significantly different from RV+SBU, IED+ADU, PHF+SBU, or PHI+ADU (P>.05). Group RV+SBU did not differ statistically from the remaining groups (P>.05). Film thickness evaluation revealed the lowest values for RV+SBU, VE+ADU, FF+SBU, and IEF+ADU, with an average between groups of 0.17 mm; these groups were significantly different from FS+SBU, IED+ADU, PHF+SBU, and PHI+ADU (P>.05), with an average of 0.31 mm.
Conclusions:
Both the VS and the FT of direct restorative composite resins were higher than those of veneer cements and flowable composite resins, whether preheated or not preheated.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
09:10Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
Related Concept Videos
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Porosity in Cement Paste
The balance of water to cement in the mix is...