Related Experiment Video
Updated: Mar 12, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Pulse oximeter saturation target limits for preterm infants: a survey among European neonatal intensive care units
Maurice J Huizing1, Eduardo Villamor-Martínez2, Máximo Vento3
1Department of Pediatrics, Maastricht University Medical Center (MUMC+), P. Debyelaan 25, P.O. Box 5800, 6202 AZ, Maastricht, The Netherlands. m.huizing@mumc.nl.
Abstract:
The optimum range of pulse oximeter oxygen saturation (SpO2) for preterm infants remains controversial. Between November 2015 and February 2016, we conducted a web-based survey aimed to investigate the current and former practices on SpO2 targets in European neonatal intensive care units (NICUs). We obtained valid responses from 193 NICUs, treating 8590 newborns ≤28 weeks per year, across 27 countries. Forty different saturation ranges were reported, ranging from 82-93 to 94-99%. The most frequently utilized SpO2 ranges were 90-95% (28%), 88-95% (12%), 90-94% (5%), and 91-95% (5%). A total of 156 NICUs (81%) changed their SpO2 limits over the last 10 years. The most frequently reported former limits were 88-92% (18%), 85-95% (9%), 88-93 (7%), and 85-92% (6%). The NICUs that increased their SpO2 ranges expected to obtain a reduction in mortality. A 54% of the NICUs found the scientific evidence supporting their SpO2 targeting policy strong or very strong.
Conclusion:
We detected a high degree of heterogeneity in pulse oximeter SpO2 target limits across European NICUs. The currently used limits are 3 to 5% higher than the former limits, and the most extreme limits, such as lower below 85% or upper above 96%, have almost been abandoned. What is Known: • For preterm infants requiring supplemental oxygen, the optimum range of pulse oximeter oxygen saturation (SpO 2 ) to minimize organ damage, without causing hypoxic injury, remains controversial. What is New: • This survey highlights the lack of consensus regarding SpO 2 target limits for preterm infants among European neonatal intensive care units (NICUs). We detected 40 different SpO 2 ranges, and even the most frequently reported range (i.e., 90-95%) was used in only 28% of the 193 respondent NICUs. • A total of 156 NICUs (81%) changed their SpO 2 limits over the last 10 years. The currently used limits are 3 to 5% higher than the former limits, and the most extreme limits, such as lower below 85% or upper above 96%, have almost been abandoned.
More Related Videos
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...