Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

9.3K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.3K
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

12.0K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
12.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Multiscale structural-rheological mapping of cancer spheroids during maturation.

Soft matter·2026
Same author

Entropy-based super-resolution imaging in waveguide-based TIRF microscopy-an experimental and numerical study.

Optics express·2025
Same author

Tapered tip optical fibers for measuring ultra-small refractive index changes with record high sensitivity.

Optics letters·2023
Same author

Investigating the Potential of Thin Silicon Nitride Membranes in Fiber-Based Photoacoustic Sensing.

Sensors (Basel, Switzerland)·2023
Same author

Sub-Nanometer Acoustic Vibration Sensing Using a Tapered-Tip Optical Fiber Microcantilever.

Sensors (Basel, Switzerland)·2023
Same author

Asymmetric, non-uniform 3-dB directional coupler with 300-nm bandwidth and a small footprint.

Optics letters·2023

Related Experiment Video

Updated: Mar 12, 2026

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

Published on: August 4, 2018

9.0K

Design of a high-speed multiple-reference optical coherence tomography system.

B Imran Akca

    Optics Express
    |November 19, 2016
    PubMed
    Summary

    This study presents a novel multiple-reference time domain optical coherence tomography (OCT) system that eliminates the need for a mechanical scanner. This advancement significantly enhances imaging speed for faster medical diagnostics.

    Area of Science:

    • Biomedical Optics
    • Medical Imaging Technology

    Background:

    • Time domain optical coherence tomography (TD-OCT) systems are crucial for non-invasive imaging.
    • Current TD-OCT systems face limitations in imaging speed due to mechanical scanning mirrors.

    Purpose of the Study:

    • To develop an integrated-optics-based multiple-reference TD-OCT system.
    • To overcome the speed limitations inherent in traditional TD-OCT systems.

    Main Methods:

    • An integrated-optics-based system utilizing electro-optically controlled switches.
    • Sequential tapping of reference and sample lights at multiple locations.
    • Elimination of the mechanical scanner.

    Main Results:

    • Achieved an axial resolution of 20 µm.

    More Related Videos

    Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
    11:21

    Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

    Published on: January 15, 2013

    12.0K
    Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
    12:54

    Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo

    Published on: October 2, 2021

    3.7K

    Related Experiment Videos

    Last Updated: Mar 12, 2026

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
    12:22

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

    Published on: August 4, 2018

    9.0K
    Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
    11:21

    Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

    Published on: January 15, 2013

    12.0K
    Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
    12:54

    Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo

    Published on: October 2, 2021

    3.7K
  • Targeted a depth range of 1 mm at a central wavelength of 800 nm.
  • Demonstrated potential for significantly improved imaging speed.
  • Conclusions:

    • The proposed multiple-reference TD-OCT system effectively removes the mechanical scanner.
    • This design offers a substantial increase in imaging speed for OCT applications.
    • Paves the way for faster and more efficient optical coherence tomography.