Related Experiment Video
Updated: Mar 11, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Survey of Effective Doses to Patients Undergoing Contrast-Based X-ray Fluoroscopy Procedures in Tanzania
J E Ngaile1, P K Msaki1, R R Kazema2
1Department of Physics, University of Dar es Salaam, PO Box 35063, Dar es Salaam, Tanzania.
Abstract:
The aim of this study was to assess the radiation burden imparted to patients from contrast-based X-ray fluoroscopy procedures in Tanzania. The effective doses (EDs) to patients from five contrast-based fluoroscopy procedures were obtained from four hospitals. The ED was estimated using the knowledge of the patient characteristics, patient-related exposure parameters, measurements of air kerma area product and PCXCM software. The median EDs for the barium swallow (BS), barium meal (BM), barium enema (BE), hysterosalpingography (HSG) and retrograde urethrography (RUG) were 0.50, 1.43, 2.83, 0.65 and 0.59 mSv, respectively. The median ED per hospital for the BS and BM procedures varied by factors of up to 9.9 and 4.2, respectively, while for the BE, HSG and RUG varied by factors of up to 2.3, 2.4 and 4.3, respectively. The overall differences between individual EDs across the four hospitals varied by factors of up to 53, 58.9 and 11.4 for the BS, BM and BE, respectively, while for the HSG and RUG differed by factors of up to 22 and 46.7, respectively. The mean EDs in this study were mostly lower than reported values from Spain, the UK, Ghana and Greece, while slightly higher than those reported from India. The observed wide variations of procedural protocols and patient doses within and across the hospitals; and the observed high patient doses in this study relative to those from the literature call for the need to standardize procedural protocols and optimize contrast-based fluoroscopy procedures.
More Related Videos
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VII: Vascular Imaging