Related Experiment Video
Updated: Jun 4, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Patient-size-dependent radiation dose optimisation technique for abdominal CT examinations
J E Ngaile1, P Msaki, R Kazema
1Directorate of Radiation Control, Tanzania Atomic Energy Commission, PO Box 743 Arusha, Tanzania. jngaile@yahoo.com
Abstract:
Since patient doses from computed tomography (CT) are relatively high, risk-benefit analysis requires dose to patients and image quality be optimised. The aim of this study was to develop a patient-dependent optimisation technique that uses patient diameter to select a combination of CT scanning parameters that minimise dose delivered to patients undergoing abdominal CT examinations. The study was performed using cylindrical phantoms of diameters ranging from 16 to 40 cm in order to establish the relationship between image degradation, CT scanning techniques, patient dose and patient size from two CT scanners. These relationships were established by scanning the phantoms using standard scanning technique followed by selected combinations of scanning parameters. The image noises through phantom images were determined using region of interest software available in both scanners. The energy depositions to the X-ray detector through phantoms were determined from measurements of CT dose index in air corrected for attenuation of the phantom materials. The results demonstrate that exposure settings (milliampere seconds) could be reduced by up to 82 % for smaller phantom relative to standard milliampere seconds, while detector signal could be reduced by up to 93 % for smaller phantom relative to energy depositions required when scanned using standard scanning protocols. It was further revealed that the use of the object-specific scanning parameters on studies performed with phantom of different diameters could reduce the incident radiation to small size object by up to 86 % to obtain the same image quality required for standard adult object. In view of the earlier mentioned fact, substantial dose saving from small-sized adults and children patients undergoing abdomen CT examinations could be achieved through optimal adjustment of CT scanning technique based on the patient transverse diameter.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT

