Related Experiment Video
Updated: Mar 11, 2026

Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students
Published on: June 16, 2018
Utilizing a Wristband Sensor to Measure the Stress Level for People with Dementia
Basel Kikhia1, Thanos G Stavropoulos2, Stelios Andreadis3
1Department of Health Sciences, Luleå University of Technology, 97187 Luleå, Sweden. basel.kikhia@ltu.se.
Abstract:
Stress is a common problem that affects most people with dementia and their caregivers. Stress symptoms for people with dementia are often measured by answering a checklist of questions by the clinical staff who work closely with the person with the dementia. This process requires a lot of effort with continuous observation of the person with dementia over the long term. This article investigates the effectiveness of using a straightforward method, based on a single wristband sensor to classify events of "Stressed" and "Not stressed" for people with dementia. The presented system calculates the stress level as an integer value from zero to five, providing clinical information of behavioral patterns to the clinical staff. Thirty staff members participated in this experiment, together with six residents suffering from dementia, from two nursing homes. The residents were equipped with the wristband sensor during the day, and the staff were writing observation notes during the experiment to serve as ground truth. Experimental evaluation showed relationships between staff observations and sensor analysis, while stress level thresholds adjusted to each individual can serve different scenarios.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment: