Analysis of tricyclic antidepressants in human plasma using online-restricted access molecularly imprinted solid
Mariane Gonçalves Santos1, Isabela Maria Campos Tavares1, Adriano Francisco Barbosa1
1Toxicants and Drugs Analysis Laboratory - LATF, Faculty of Pharmaceutical Sciences, Federal University of Alfenas - Unifal-MG, 700 Gabriel Monteiro da Silva Street, 37130-000 Alfenas, MG, Brazil.
Abstract:
The use of a new class of hybrid materials, called restricted access molecularly imprinted polymers (RAMIPs) seems to present a good strategy for the sample preparation of complex matrices, since these materials combine good protein elimination capacity with high degree selectivity. Mass spectrometers (MS) have been successfully used for polar drug identification and quantification. In order to combine the advantages of both RAMIPs and mass spectrometry, we proposed a study that joins these properties in a single system, where we could analyse tricyclic antidepressants from human plasma, without offline extraction or chromatographic separation. A RAMIP for amitriptyline was synthesised by the bulk method, using methacrylic acid as a functional monomer and glycidilmethacrylate as a hydrophilic co-monomer. Then, epoxide ring openings were made and the polymer was covered with bovine serum albumin (BSA). A column filled with RAMIP-BSA was coupled to a MS/MS instrument in an online configuration, using water as loading and reconditioning mobile phase and a 0.01% acetic acid aqueous solution: acetonitrile at 30:70 as elution mobile phase. The system was used for on-line extraction and simultaneous quantification of nortriptyline, desipramine, amitriptyline, imipramine, clomipramine and clomipramine-d3 (IS) (from 15.0 to 500.0μgL-1) from plasma samples. The correlation coefficient was higher than 0.99 for all analytes. The CV (coefficient of variation) values ranged from 1.34% to 19.13% for intra assay precision and 1.32-19.77% for inter assay precision. The E% (relative error) values ranged from -19.15% to 19.51% for intra assay accuracy and from -9.04% to 16.22% for inter assay accuracy.
More Related Videos
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
12:21Thermostabilization, Expression, Purification, and Crystallization of the Human Serotonin Transporter Bound to S-citalopram
Published on: November 27, 2016