Related Experiment Video
Updated: Mar 11, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Rotational Mal-Alignment after Reamed Intramedullary Nailing for tibial shaft fracture
Sher Baz Khan1, Yasir Mohib1, Rizwan Haroon Rashid1
1Orthopedics, Aga Khan University Hospital, Karachi.
Abstract:
Intra-medullary (IM) nailing is standard of care for unstable tibial shaft fractures. Malrotation is very common but it is under-recognised, inpart because of variation in normal anatomy and partly due to difficulty in accurately assessing rotation. This study was planned to evaluate the frequency of rotational mal-alignment after reamed tibia IMnailing. This cross-sectional study was conducted at Aga khan University Hospital, Karachi, and comprised patients with tibia shaft fractures managed with IMnailing from January to December 2014. All the patients were assessed intra-operatively for rotational alignment using the knee and ankle fluoroscopic images. There were 81 patients with a mean age of 38±16.9 years. There were 64(79%) male patients. Overall the incidence of malrotation was in 20(24.7%) cases. Rotational mal-alignment is one of the preventable complications after IMnailing which can be assesed intra-operatively under fluoroscope.