Related Experiment Video
Updated: Mar 11, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Intubation without use of stylet for McGrath videolaryngoscopy in patients with expected normal airway: A randomized
Hyun Jeong Kwak1, Sook Young Lee, Su Youn Lee
1Department of Anesthesiology and Pain Medicine, Gachon University, Gil Medical Center, Incheon Department of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Korea.
Background:
During McGrath videolaryngoscope (VL) intubation, a styletted endotracheal tube maintaining an upward distal tip angle is recommended by some manufacturers. However, a styletted endotracheal tube can elicit rare but potentially serious complications. The purpose of this study was to demonstrate that a nonstyletted tube with exaggerated curvature would be noninferior to a styletted tube for orotracheal intubation using McGrath VL in patients with expected normal airway, by comparing the time to intubation and ease of intubation.
Methods:
One hundred forty patients, ages 19 to 70 years (American Society of Anesthesiologists physical status I-II), undergoing tracheal intubation for elective surgery were randomly allocated to the nonstylet group (n = 70) or the stylet group (n = 70). Anesthesia induction consisted of propofol, remifentanil, and rocuronium. The primary outcome was time to intubation assessed by a blind observer. Cormack and Lehane glottic grade, easy of intubation, and intubation difficulty score (IDS) were also assessed.
Results:
Median time to intubation [interquartile range] was not different between the nonstylet group and the stylet group (26 [24-32.5] s vs 27 [25-31] s, P = 0.937). There was no significant in median IDS between the nonstylet group and the stylet group (P = 0.695).
Conclusion:
This study shows that a nonstyletted endotracheal tube with exaggerated curvature has a similar performance to a styletted tube with a hockey-stick curvature during intubation using McGrath VL regarding time taken to successful intubation and easiness of intubation.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...