Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Beech latewood density as a proxy for temperature reconstruction.

Science advances·2026
Same author

Hunting ecology predicts eye arrangements in the modular visual system of spiders.

Current biology : CB·2026
Same author

High-throughput in situ single particle X-ray imaging of dehydrating viral capsids.

Light, science & applications·2026
Same author

An induction heating system for in situ X-ray diffraction imaging: design, simulation and application to dislocation dynamics in semiconductors.

Journal of synchrotron radiation·2026
Same author

Single-Particle X-ray Scattering Reveals a High Local Supersaturation of Precursors as the Origin of CoO Assembly Formation.

The journal of physical chemistry letters·2026
Same author

High-throughput phenomics of global ant biodiversity.

Nature methods·2026

Related Experiment Video

Updated: Mar 11, 2026

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
10:28

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

Published on: July 5, 2016

10.8K

Single-distance phase retrieval algorithm for Bragg Magnifier microscope.

Stanislav Hrivňak, Jozef Uličný, Ladislav Mikeš

    Optics Express
    |December 2, 2016
    PubMed
    Summary
    This summary is machine-generated.

    This article introduces a new computational method to reconstruct high-resolution images of biological samples using only a single X-ray hologram. By applying specific mathematical constraints to the data, the researchers successfully imaged complex specimens like tardigrades. This approach improves imaging efficiency and reduces radiation exposure for delicate samples.

    Keywords:
    X-ray microscopyholographic imagingbiological specimen analysiscomputational reconstruction

    Frequently Asked Questions

    More Related Videos

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
    13:31

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

    Published on: December 22, 2015

    15.8K
    Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
    08:39

    Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

    Published on: January 28, 2019

    10.4K

    Related Experiment Videos

    Last Updated: Mar 11, 2026

    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
    10:28

    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

    Published on: July 5, 2016

    10.8K
    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
    13:31

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

    Published on: December 22, 2015

    15.8K
    Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
    08:39

    Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

    Published on: January 28, 2019

    10.4K

    Area of Science:

    • X-ray imaging within Bragg Magnifier microscopy
    • Computational physics and optics

    Background:

    No prior work had resolved the challenge of reconstructing high-resolution phase images from a lone X-ray hologram in specific microscopy setups. That uncertainty drove the development of specialized computational tools for biological imaging. It was already known that standard techniques often require multiple measurements at different distances to achieve clarity. This gap motivated the creation of a more efficient approach for delicate samples. Prior research has shown that traditional methods can be time-consuming and potentially damaging to living specimens. The current landscape lacks robust, single-shot solutions for high-magnification systems. This study addresses the need for faster, lower-dose imaging protocols. Researchers have long sought to optimize data acquisition for sensitive biological targets.

    Purpose Of The Study:

    The aim of this study is to present an improved, single-distance phase retrieval algorithm for holographic X-ray imaging. This research addresses the need for more efficient imaging of biological objects using a germanium Bragg Magnifier Microscope. The authors seek to overcome the limitations associated with traditional multi-distance data collection methods. By introducing a modified shrink-wrap algorithm, they intend to enhance the reconstruction of phase objects. The team also incorporates a robust unwrapping technique to improve the accuracy of the wavefield analysis. They are motivated by the goal of achieving dose-efficient, in-vivo imaging for sensitive biological specimens. This work explores whether a single hologram can provide sufficient data for high-resolution results. The study evaluates the performance of these new constraints on both phantom objects and complex biological samples.

    Main Methods:

    The review approach evaluates a novel computational pipeline for processing holographic X-ray data. Investigators implemented a modified shrink-wrap technique to refine the reconstruction of phase objects. They integrated a robust unwrapping procedure to handle complex wavefront data effectively. The team applied specific mathematical constraints at both the object plane and the detector plane. Testing involved phantom objects to validate the accuracy of the proposed mathematical model. Researchers then applied the framework to complex biological specimens, specifically the tardigrade. They utilized the Fourier spectral power method to determine the spatial resolution of the resulting images. This systematic evaluation confirms the performance of the algorithm across diverse sample types.

    Main Results:

    The strongest finding shows that the algorithm successfully reconstructs images from a single hologram with a spatial resolution of approximately 300 nanometers. This resolution value remains consistent when comparing biological specimens to reconstructed test patterns. The researchers confirmed the suitability of their approach by imaging the tardigrade, a complex biological specimen. These results demonstrate that the method effectively handles the challenges of single-shot data acquisition. The data indicate that the new constraints significantly improve the quality of the phase retrieval process. The study achieved successful reconstruction without the need for multiple distance measurements. These findings validate the potential for dose-efficient imaging protocols in this microscopy configuration. The performance metrics highlight the reliability of the algorithm for high-resolution biological observations.

    Conclusions:

    The authors propose that their refined computational framework enables high-quality imaging from a solitary hologram. This synthesis suggests that the technique is well-suited for delicate biological specimens. The findings imply that the method maintains consistent spatial resolution across different types of samples. The researchers confirm that their approach supports dose-efficient imaging requirements. This work demonstrates the utility of the system for in-vivo observations. The study indicates that the integration of specific constraints improves overall reconstruction reliability. The team concludes that their method expands the practical capabilities of the microscope. These results highlight a path toward faster, safer imaging workflows for future biological investigations.

    The researchers utilize a modified shrink-wrap algorithm combined with a robust unwrapping process. These tools apply specific constraints to the wavefield at both the object and detector planes to extract phase information from a single hologram.

    The team employs a germanium Bragg Magnifier Microscope, which provides the high-magnification platform necessary for imaging. This instrument is specifically designed for in-line holographic X-ray imaging of biological objects.

    A single-distance measurement is necessary because it minimizes the radiation dose delivered to the specimen. This approach avoids the complexity of multi-distance setups while maintaining high-quality reconstruction capabilities.

    The Fourier spectral power method serves as the primary data analysis tool. It quantifies the spatial resolution of the reconstructed images, confirming a resolution of approximately 300 nanometers for the biological samples.

    The researchers measured the spatial resolution of the reconstructed images. They found that the system achieves a resolution of approximately 300 nanometers, which matches the performance observed in test patterns.

    The authors propose that their method confirms the potential for in-vivo, dose-efficient imaging. They suggest this capability is particularly beneficial for studying biological objects that require minimal radiation exposure.