Dual Energy CT Pulmonary Angiography with 6g Iodine-A Propensity Score-Matched Study
Andreas Meier1, Kai Higashigaito1, Katharina Martini1
1Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Objective:
To evaluate the performance of low contrast media (CM) dose dual-energy computed tomography pulmonary angiography (CTPA) with advanced monoenergetic reconstructions in patients with suspected pulmonary embolism (PE).
Materials And Methods:
The study had institutional review board approval; all patients gave written informed consent. Forty-one patients (25 men, 16 women, mean age 62.9±14.7 years) undergoing low CM dose (15ml, 6g iodine) dual-energy CTPA with advanced monoenergetic reconstructions were matched via propensity-scoring based on logistic regression analysis with a comparison group of 41 patients (24 men, 17 women, mean age 62.7±13.9 years) undergoing standard CM dose single-energy CTPA (80ml, 24g iodine). Subjective (noise, artifacts) and objective (attenuation, noise, contrast-to-noise ratio (CNR)) image quality was assessed by two blinded, independent readers. All patients underwent clinical follow-up after three months for evaluation of adverse events.
Results:
Interrater agreement for subjective image quality in both groups ranged from fair to excellent (ICC: 0.46-0.84); agreement for objective image quality was excellent (ICC: 0.83-0.93). There was no significant difference regarding subjective noise (p = 0.15-0.72) and artifacts (p = 0.16-1) between the low and the standard CM dose group. There was no significant difference regarding CNR between the CM dose groups (p = 0.11-0.87). Seven of the 41 (17%) patients in the low and 5/41 (12%) in the standard CM dose group were diagnosed with PE (p = 0.32). No patient suffered from subsequent PE or PE-associated death during the follow-up period.
Conclusion:
Dual-energy CTPA with advanced monoenergetic reconstruction is feasible with 6g iodine and allows for the diagnosis and safe exclusion of central, lobar, and segmental PE.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET