Related Experiment Video For Branchial cleft cyst
Updated: Mar 10, 2026

Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
18F-FDG PET/CT to differentiate malignant necrotic lymph node from benign cystic lesions in the neck
Peymaneh Abadi1, Allan Johansen2, Christian Godballe3
1Department of Nuclear Medicine, Odense University Hospital, Søndre Boulevard 29, 5000, Odense C, Denmark. pey.abadi@gmail.com.
Objective:
Patients presenting with cystic lesions in the neck without obvious signs of malignancy constitute a diagnostic challenge since fine needle aspiration is often insufficient and a diagnosis may not be reached until surgical resection/biopsy is performed. The differential diagnosis of a cystic cervical mass comprises a variety of benign conditions, but malignancy must be ruled out. We examined the diagnostic performance of fluorine-18 fluorodeoxyglucose (18F-FDG) PET/CT to identify malignancy.
Methods:
We retrospectively included consecutive patients referred from the Department of ENT Head and Neck Surgery for 18F-FDG PET/CT-scans because of a solitary neck cyst. Scan results were compared to histopathology and follow-up.
Results:
The study comprised 58 patients. Twenty patients (34%) were diagnosed with cancer during follow-up. PET/CT suggested malignancy in 34 patients (19 true positive, 15 false positive) and showed no malignancy in 24 (23 true negative, 1 false negative). The sensitivity, specificity, accuracy, positive and negative predictive values were 95% (76-99%), 61% (45-74%), 72% (60-82%), 56% (39-71%), and 96% (80-99%), respectively (95% confidence intervals in brackets). The primary tumor was identified in 14 out of the 20 patients with confirmed cancer. Increased metabolism, as evaluated by PET, was the only imaging characteristic among several others, which associated independently with malignancy in the cystic neck lesions, odds ratio 1.27 (1.07-1.50), p = 0.006.
Conclusion:
18F-FDG PET/CT could reliably rule out malignancy (NPV 96%), albeit with a high frequency of false positive scans, requiring further diagnostic work-up. Increased metabolism was the best imaging parameter to differentiate between malignant and benign lesions.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...