Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict
Sheila Nainan Myatra1, Natesh R Prabu, Jigeeshu Vasishtha Divatia
11Department of Anesthesiology, Critical Care and Pain, Tata Memorial Hospital, Mumbai, India. 2AP-HP, Hôpitaux Universitaires Paris-Sud, Hôpital de Bicêtre, Service de réanimation médicale, Le Kremlin-Bicêtre, France.
Objectives:
Stroke volume variation and pulse pressure variation do not reliably predict fluid responsiveness during low tidal volume ventilation. We hypothesized that with transient increase in tidal volume from 6 to 8 mL/kg predicted body weight, that is, "tidal volume challenge," the changes in pulse pressure variation and stroke volume variation will predict fluid responsiveness.
Design:
Prospective, single-arm study.
Setting:
Medical-surgical ICU in a university hospital.
Patients:
Adult patients with acute circulatory failure, having continuous cardiac output monitoring, and receiving controlled low tidal volume ventilation.
Interventions:
The pulse pressure variation, stroke volume variation, and cardiac index were recorded at tidal volume 6 mL/kg predicted body weight and 1 minute after the "tidal volume challenge." The tidal volume was reduced back to 6 mL/kg predicted body weight, and a fluid bolus was given to identify fluid responders (increase in cardiac index > 15%). The end-expiratory occlusion test was performed at tidal volumes 6 and 8 mL/kg predicted body weight and after reducing tidal volume back to 6 mL/kg predicted body weight.
Results:
Thirty measurements were obtained in 20 patients. The absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight predicted fluid responsiveness with areas under the receiver operating characteristic curves (with 95% CIs) being 0.99 (0.98-1.00) and 0.97 (0.92-1.00), respectively. The best cutoff values of the absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight were 3.5% and 2.5%, respectively. The pulse pressure variation, stroke volume variation, central venous pressure, and end-expiratory occlusion test obtained during tidal volume 6 mL/kg predicted body weight did not predict fluid responsiveness.
Conclusions:
The changes in pulse pressure variation or stroke volume variation obtained by transiently increasing tidal volume (tidal volume challenge) are superior to pulse pressure variation and stroke volume variation in predicting fluid responsiveness during low tidal volume ventilation.
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Measurement of Blood Pressure
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...