Related Experiment Video
Updated: Mar 10, 2026

Description of a Swine Infant Model of Volume-Controlled Hemorrhagic Shock
Published on: November 3, 2023
Lactate - Arterial and Venous Agreement in Sepsis: a prospective observational study
Deepankar Datta1,2, Julia Grahamslaw1,2, Alasdair J Gray1,2
1Emergency Medicine Research Group Edinburgh, Department of Emergency Medicine.
Background:
Sepsis is a common condition in the emergency department (ED). Lactate measurement is an important part of management: arterial lactate (A-LACT) measurement is the gold standard. There is increasing use of peripheral venous lactate (PV-LACT); however, there is little research supporting the interchangeability of the two measures.If PV-LACT has good agreement with A-LACT, it would significantly reduce patient discomfort and the risks of arterial sampling for a large group of acutely unwell patients, while allowing faster and wider screening, with potential reduced costs to the healthcare system.
Objective:
The aim of this study is to determine the agreement between PV-LACT and A-LACT in septic patients attending the ED.
Methods:
We carried out a prospective observational cohort study of 304 consented patients presenting with sepsis to a single UK NHS ED (110 000 adult attendances annually) taking paired PV-LACT and A-LACT. Bland-Altman analysis was carried out to determine agreement. Receiver operating characteristic curves and 2×2 tables were constructed to explore the predictive value of PV-LACT for A-LACT.
Results:
The mean difference (PV-LACT-A-LACT) is 0.4 mmol/l [95% confidence interval (CI): 0.37-0.45], with 95% limits of agreement from -0.4 (95% CI: -0.45 to -0.32) to 1.2 (95% CI: 1.14-1.27). A PV-LACT of at least 2 mmol/l predicts an A-LACT of at least 2 with 100% sensitivity (95% CI: 89-100%) and 83% specificity (95% CI: 77-87%).
Conclusion:
This study is the largest comparing the two measurements, and shows good clinical agreement. We recommend using PV-LACT in the routine screening of septic patients. A PV-LACT less than 2 mmol/l is predictive of an A-LACT less than 2 mmol/l.
Related Concept Videos
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Disorders of Acid-Base Balance
Respiratory Acidosis and Alkalosis
Respiratory acidosis occurs due to an increase in the partial pressure of carbon dioxide PCO2 in the blood. It often arises from shallow breathing or impaired gas exchange caused by...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies