Cross Section of Legislative Approaches to Reducing Indoor Dampness and Mold

Jennifer L Major1, Gerald W Boese

  • 1Ross Strategic, Seattle, Washington.

Related Concept Videos

Mortar Joint Deterioration in Masonry01:13

Mortar Joint Deterioration in Masonry

Mortar joint deterioration is a significant concern in masonry structures, with water accumulation in the joints leading to damage from freeze-thaw cycles. The repeated expansion of water during freezing and its melting during thawing develop and propagate cracks in the masonry joints. Eventually, this leads to the spalling of mortar from the joints, loosening masonry units and weakening the structure. The deteriorated mortar joints are also vulnerable to moisture intrusion into the walls.
The...
381
Seasoning of Wood01:15

Seasoning of Wood

Seasoning of wood is a crucial process aimed at reducing and stabilizing the moisture content within the wood to prevent future shrinkage, structural damage, or aesthetic issues once the wood is used in construction. Wood naturally swells when it absorbs moisture and contracts as it dries.
Achieving equilibrium moisture content is the goal of seasoning; this is the point where the wood's moisture content stabilizes to align with the moisture levels of the surrounding environment. Proper...
603
Cavity Drainage and Flashings in Masonry walls01:20

Cavity Drainage and Flashings in Masonry walls

Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
528
Masonry in Cold and Hot Weather Conditions01:21

Masonry in Cold and Hot Weather Conditions

In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
362
Waterproofing and Anti-Bacterial Admixtures in Concrete01:22

Waterproofing and Anti-Bacterial Admixtures in Concrete

Concrete's susceptibility to water absorption is due to the capillary action within the pores of its hydrated cement paste. This action draws water in, creating the need for waterproofing admixtures to prevent such penetration. The efficacy of these admixtures is contingent upon the water pressure, with variations arising from different conditions such as rain, capillary rise, or hydrostatic pressure in structures intended to hold water.
Waterproofing admixtures render concrete hydrophobic,...
269
Strategies for Assessing and Addressing Confounding01:25

Strategies for Assessing and Addressing Confounding

Confounding is a critical issue in epidemiological studies, often leading to misleading conclusions about associations between exposures and outcomes. It occurs when the relationship between the exposure and the outcome is mixed with the effects of other factors that influence the outcome. Given that, addressing confounding is of high importance for drawing accurate inferences in research.
Confounding can be addressed at both the design phase of a study and through analytical methods after data...
505