Related Experiment Video
Updated: Mar 10, 2026

Measuring the Complete-arch Distortion of an Optical Dental Impression
Published on: May 30, 2019
Effects of Image Compression on Linear Measurements of Digital Panoramic Radiographs
Leonardo Francisco Provedel1, Bruna Natália Alves da Silva Pimentel1, Tarcísio Martins de Jesus1
1Dental School, UFBA - Universidade Federal da Bahia, Salvador, BA, Brazil.
Abstract:
This study aimed to evaluate the accuracy of panoramic radiographs obtained by digital system based on charge coupled device (CCD) and a phosphor storage plate (PSP) system with two different file formats, JPEG irreversible type and BMP. Linear measurements of artificial bony defects were made in dry mandibles with a digital caliper. Measures of digital panoramic radiographs were taken in ImageJ(r) software. Each measurement was performed twice by an experienced examiner. The intra-rater agreement was considered very strong (Pearson's correlation coefficient of 0.97). There was no significant difference between the linear measurements of dry mandibles, considered the gold standard, in relation to measurements obtained from digital radiographs (p=0.47). The error of these measures for the CCD was 1.04 mm (9.97%) for JPEG images and 1.03 mm (9.99%) for those with BMP format. For the PSP images, these values were 1.48 mm (14.94%) and 1.43 mm (14.43%), respectively. Although there was no statistical difference between the images with JPEG and BMP format, for both digital systems (p=1.00 for CCD and p=0.98 for PSP system), errors made on radiographs obtained by PSP system were significantly higher than those of CCD (p<0.05). The size of the files saved in JPEG was also significantly lower (p=0.005) compared with the files saved in BMP. It may be concluded that the digital radiographs, both saved in JPEG and BMP formats, are accurate, regardless the used digital system, and JPEG images are more suitable for teleradiology.
Related Concept Videos
Imaging Studies III: Computed Tomography
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT