Related Experiment Video
Updated: Mar 10, 2026

Seeding and Implantation of a Biosynthetic Tissue-engineered Tracheal Graft in a Mouse Model
Published on: April 1, 2019
The "Hitch Stitch": An Effective Method of Preventing Migration in High Tracheal Stenosis
Ravindra M Mehta1, Abhinav Singla, Aashish Shah
1Department of Pulmonary, Critical Care and Sleep Medicine, Apollo Hospitals, Bangalore, India.
Background:
The incidence of caudal stent migration in high tracheal stenting is 13-21% and is common with silicone stents. This can lead to major problems, including emergency repeat procedures. Several antimigration methods are described, but have limitations in terms of their success rate, availability, cost or ease of the procedure.
Objectives:
We describe an innovative method of stent migration prevention using a simple percutaneous anchoring "hitch stitch", validated in a large series.
Methods:
After tracheal stent placement, an Ethilon suture was passed into the stent lumen through an 18-G needle. To take this suture back to the exterior to complete the stitch, a retrieval loop was passed through another 14-G percutaneous cannula inserted into the stent lumen. Bronchoscopically, using a forceps the first suture was pulled inside the loop, the loop was retracted, the suture was exteriorized, and the knot was completed and embedded subcutaneously. While removing the stent, an endoscopic scissor was used to cut the stitch to free the stent.
Results:
A total of 42 "hitch stitches" were done in 29 patients over 5 years, predominantly for silicone stents. Indications for stenting included postintubation tracheal stenosis (83.3%), malignancy (11.9%) and tracheoesophageal fistula (4.8%, metal stents). The procedure was successful in 41/42 (97.6%) patients. Stitch removal was uncomplicated.
Conclusion:
This is the largest series of an external stent anchoring procedure as a migration prevention strategy in high tracheal stenting, applicable to both silicone and metal stents. Stent migration prevention using this "hitch stitch" is simple, safe and successful, without any complications during stent removal.
More Related Videos
08:26Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
09:10Heterotopic and Orthotopic Tracheal Transplantation in Mice used as Models to Study the Development of Obliterative Airway Disease
Published on: January 20, 2010
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Suctioning II: Procedure