Generalized paired-agent kinetic model for in vivo quantification of cancer cell-surface receptors under receptor

N Sadeghipour1, S C Davis2, K M Tichauer1

  • 1Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616, USA.

Insights

A new generalized simplified reference tissue model (GSRTM) accurately estimates cancer receptor concentration, even when receptors are saturated. This advance is crucial for precision medicine drug studies and quantitative molecular imaging.

Area of Science:

  • Molecular Imaging and Precision Medicine
  • Quantitative Analysis of Biological Receptors

Background:

  • Precision medicine drugs target cell-surface cancer receptors, making receptor availability critical for efficacy.
  • Current paired-agent molecular imaging methods for receptor status require low imaging agent concentrations, limiting applications like drug binding studies.

Purpose of the Study:

  • To develop a generalized simplified reference tissue model (GSRTM) for paired-agent imaging applicable to both non-receptor-saturated and receptor-saturated conditions.
  • To extend the utility of quantitative imaging beyond trace-level imaging agent concentrations.

Main Methods:

  • Development of the generalized simplified reference tissue model (GSRTM).
  • Extensive simulation studies to compare GSRTM with the standard simple reference tissue model (SRTM) under varying receptor saturation levels.
  • Validation using in vivo mouse tumor xenograft data comparing GSRTM and SRTM estimates.
  • Development of a 'rule-of-thumb' algorithm to estimate receptor saturation levels.

Main Results:

  • GSRTM provides more accurate tumor receptor concentration estimates than SRTM under receptor-saturation conditions (0% ± 1% error vs. 50% ± 1% error).
  • GSRTM accuracy matches SRTM in non-saturated conditions (5% ± 5% error vs. 0% ± 5% error).
  • In vivo data showed GSRTM estimates deviating from SRTM in tumors likely experiencing receptor saturation.
  • GSRTM is recommended for use when receptor saturation exceeds 20%.

Conclusions:

  • The GSRTM accurately measures receptor concentrations under saturation conditions, essential for high-dose drug studies and optimizing signal-to-noise in molecular imaging.
  • This model enhances quantitative PET and SPECT imaging by providing accurate measurements even with noisier data.
  • The developed algorithm aids in predicting receptor saturation levels for experimental design.