Related Experiment Video
Updated: Mar 9, 2026

Determining Glucose Metabolism Kinetics Using 18F-FDG Micro-PET/CT
Published on: May 2, 2017
Frequency of high blood glucose prior to FDG PET
Amir H Khandani1, Isabel M Bravo2, Parth S Patel2
1Division of Nuclear Medicine, Department of Radiology, UNC School of Medicine, CB#7510, Chapel Hill, NC, 27599-7510, USA. khandani@med.unc.edu.
Purpose:
To assess the frequency of blood glucose level higher than 150 mg/dL in non-diabetic patients presenting for FDG PET.
Methods:
We reviewed the electronic medical record (EMR) of all lymphoma patients who had at least one FDG PET/CT from July 1, 2014 through June 30, 2015. We extracted the blood glucose level at the time of the FDG PET during this 1-year time period and any previous PET scans these patients had. Patients' diabetic status was determined from EMR.
Results:
One hundred seventeen patients with 574 scans were included: 91 non-diabetic with 429 scans and 26 diabetic patients with 145 scans. Blood glucose level ranged from 44 to 259 mg/dL: 44 to 144 mg/dL in non-diabetic patients and 73 to 259 mg/dL in diabetic patients. There was no non-diabetic patient with a glucose level higher than 150 mg/dL at any occasion. Only one scan was performed with 144 mg/dL of glucose. All other scans were performed with a glucose level less than 140 mg/dL. There were nine diabetic patients with glucose level less than 150 mg/dL prior to all of their scans and 17 diabetic patients with a glucose level higher than 150 mg/dL prior to PET at least on one occasion.
Conclusions:
In all non-diabetic patients, blood glucose level was below the lower limit of the recommended range prior to all their FDG PET scans while this was not the case in diabetic patients. We conclude that measuring blood glucose level prior to FDG PET may be limited to diabetic patients.
More Related Videos
09:58Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
Published on: November 9, 2018
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
Related Concept Videos
Hypoglycemia and Glucagon
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Diabetes: Symptoms, Diagnosis, and Complications
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET