Is There a Relationship Between Body Mass Index and Fluoroscopy Time During Cervical Interlaminar Epidural Steroid
Zachary L McCormick1, Ryan Mattie2, Ali Ebrahimi3
1Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, California.
Body Mass Index (BMI) did not significantly impact fluoroscopy time during cervical interlaminar epidural steroid injections (CIESI). Obese patients showed slightly longer times than overweight patients, but overall, BMI is not a major factor in CIESI fluoroscopy duration.
Area of Science:
- Pain Medicine
- Medical Imaging
- Radiology
Background:
- Medical imaging challenges exist for patients with higher Body Mass Index (BMI).
- Limited data addresses the relationship between BMI and fluoroscopy time in cervical interlaminar epidural steroid injections (CIESI).
Purpose of the Study:
- To investigate the correlation between patient BMI and fluoroscopy duration during CIESI.
Main Methods:
- Retrospective cohort study of 366 patients undergoing fluoroscopically guided CIESI.
- Patients were categorized by BMI: normal (<25.0 kg/m²), overweight (25.0-29.9 kg/m²), and obese (≥30.0 kg/m²).
- Fluoroscopy times were compared across BMI groups using analysis of variance.
Main Results:
- Mean fluoroscopy time was 18±10 seconds across all procedures.
- Obese patients had significantly longer fluoroscopy times compared to overweight patients (P=0.02).
- BMI did not significantly affect fluoroscopy time for normal weight versus overweight or normal weight versus obese patients.
Conclusions:
- BMI does not appear to significantly influence fluoroscopy time in CIESI.
- Further research is warranted to quantify radiation exposure and health risks for patients and practitioners.