Related Experiment Video
Updated: Mar 9, 2026

A High-Throughput Method For Zebrafish Sperm Cryopreservation and In Vitro Fertilization
Published on: July 6, 2009
The effects of storing and transporting cryopreserved semen samples on dry ice
David Til1, Vera L L Amaral1, Rafael A Salvador1
1Vale do Itajaí University - UNIVALI - Itajaí/SC, Brazil.
Objective:
This study aimed to test the effects on sperm viability of transporting cryopreserved semen samples on dry ice.
Methods:
Twenty normozoospermic semen samples were cryopreserved and divided into five groups. The samples in Group 1 were immersed in liquid nitrogen throughout the experiment in cryogenic storage tanks; the cryopreserved straws in Group 2 were placed in a Styrofoam box containing dry ice and kept under these conditions for 48 hours; the samples in Group 3 were kept for 48 hours on dry ice under the same conditions as the Group 2 samples, and were then moved to a storage tank filled with liquid nitrogen; Group 4 samples were also kept for 48 hours in dry ice storage, and the Styrofoam box containing the samples was shipped by plane to assess the effects of shipping; the samples in Group 5 were shipped together with the Group 4 samples and were placed in a storage tank with liquid nitrogen after spending 48 hours stored on dry ice. After thawing, sperm parameters were analyzed for viability, vitality, and motility; spermatozoa were also tested for mitochondrial activity.
Results:
Significant decreases in motility recovery rates (P=0.01) and vitality (P=0.001) were observed in all groups when compared to the control group. Mitochondrial activity was significantly decreased only in Group 5 (P=0.04), as evidenced by greater numbers of sperm cells not stained by reagent 3,3'-diaminobenzidine.
Conclusions:
Transportation did not affect the quality of cryopreserved semen samples, but dry ice as a means to preserve the samples during transportation had detrimental effects upon the sperm parameters assessed in this study.