Related Experiment Video
Updated: Mar 9, 2026

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Preoperative Insight Into the Quality of Radial Artery Grafts
Petar Vukovic1, Miodrag Peric1, Sandra Radak2
11 Department of Cardiac Surgery, Dedinje Cardiovascular Institute, Belgrade, Republic of Serbia.
Abstract:
We investigated the impact of preoperative ultrasonography of the forearm circulation on radial artery conduit selection. Preoperative ultrasound of the forearm circulation was performed routinely in 536 patients planned for radial artery harvesting. The safety assessment of the harvest included the following algorithm of tests: the ultrasound, the Allen test, and pulse oximetry. The quality criteria that were used to exclude a radial artery from harvesting were small size of the artery, diffuse atherosclerosis, calcifications, and severe neointimal hyperplasia. The overall rejection rate due to safety reasons was 16.4%. Seventy-one (13.2%) radial arteries did not fulfill the conduit quality criteria and consequently these arteries were not harvested. In 13.4% of radial arteries, localized arterial wall disease was found in the distal third of the artery. The distal part of the artery was discarded and the rest was used as a conduit. Our results indicate that the ultrasound provides an accurate preoperative insight into the radial artery morphology, enabling selection of the arteries with favorable morphological features.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Peripheral Artery Disease V: Postoperative Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

