Increasing sex differences in the use of cardiac resynchronization therapy with or without implantable
Neal A Chatterjee1, Rasmus Borgquist2, Yuchiao Chang3
1Cardiac Arrhythmia Service and Division of Cardiology, GRB 109, Massachusetts General Hospital Heart Center, 55 Fruit Street, Boston, MA 02114, USA.
Aims:
Previous studies have identified sex disparities in the use of cardiac resynchronization therapy (CRT) and implantable cardioverter defibrillators (ICD), although the basis of underutilization in women remains poorly understood. The aim of this study was to assess sex differences in patterns of CRT use with our without ICD.
Methods And Results:
In this cross-sectional study using the National Inpatient Sample database we identified 311 009 patients undergoing CRT implantation in the United States between 2006 and 2012. Demographic and clinical characteristics were compared between men and women undergoing CRT implantation, with special attention to clinical predictors of left ventricular reverse remodelling (CRT response, score range: 0-4) and reduced ICD efficacy (score range: 0-7). When compared to men, women undergoing CRT implantation were significantly more likely to have ≥ 3 predictors of CRT response (47.3 vs. 33.2%, P < 0.001) and less likely to have ≥3 predictors of reduced ICD efficacy (27.0 vs. 37.3%, P < 0.001). Despite this, men were significantly more likely to undergo CRT with ICD (CRT-D) as the type of CRT (88.6 vs. 80.1% of all CRT implants). Compared to those with the greatest likelihood of CRT response (score ≥ 3), those with the least likelihood of CRT response had a significant decreased odds of CRT-D implant (adj odds ratio 0.27 [0.24-0.31], P < 0.001), with a greater decreased odds in women compared to men (P, for sex interaction <0.001). The difference in the % of CRT-D implant in men vs. women increased over the study period (P, sex Δ time trend = 0.012).
Conclusion:
In this large, contemporary cohort, sex differences in CRT-D implantation were inversely related to predicted CRT efficacy and have increased over time. Future efforts to narrow the gap in CRT-D implantation in men and women may help better align device selection with those most likely to benefit.
More Related Videos
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Heart Failure VI: Adjunct Therapies
Cardiopulmonary Resuscitation III: AED Use