Related Experiment Video
Updated: Mar 8, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Anesthetic Management of a Child With Jeune Syndrome for Tracheotomy: A Case Report
Masakazu Kotoda1, Tadahiko Ishiyama, Katsumi Okuyama
1From the *Department of Anesthesiology, Faculty of Medicine, University of Yamanashi, Yamanashi, Japan; †Surgical Center, University of Yamanashi Hospital, University of Yamanashi, Yamanashi, Japan; and ‡Department of Anesthesia, Shizuoka Children's Hospital, Shizuoka, Japan.
Abstract:
Jeune syndrome is a rare autosomal-recessive skeletal disorder. Anesthetic management of these patients is often difficult because of thoracic and lung hypoplasia. A 5-month-old boy with Jeune syndrome was scheduled to undergo a tracheotomy. Despite 5-minute preoxygenation with continuous positive airway pressure, the patient's oxygen saturation rapidly dropped during the induction of anesthesia. The continuous positive airway pressure should have been titrated to effective tidal volume during preoxygenation to recruit the patient's functional residual capacity and to prevent desaturation. During tracheotomy, volume-controlled ventilation with a high respiratory rate and sufficient inspiratory time effectively improved the patient's respiratory status.
Related Concept Videos
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...