His-Bundle Pacing for Identifying Optimal Ablation Sites in Patients Undergoing Atrioventricular Junction Ablation:
Nitin Kulkarni1, Curtiss Moore1, Ambarish Pandey1
1Division of Cardiology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas.
Background:
Atrioventricular (AV) junction (AVJ) ablation is conventionally performed by localizing the His-bundle electrogram (HBE). Identification of HBE in the presence of atrial fibrillation (AF) can be difficult, and can make this simple procedure challenging. In this study, we describe our experience with an alternative approach to localize optimal ablation sites using His-bundle pacing (HBP).
Methods:
Between 1/1/2014 and 12/31/2015, we performed 13 AVJ ablations using the standard electrogram-guided approach and 11 ablations using HBP. All cases utilized a long femoral guiding sheath and an 8-mm-tip electrode radiofrequency (RF) energy ablation catheter. Pacing was performed at high output (10 mA at 2 ms) to initially achieve right bundle branch capture. The catheter was withdrawn until a narrow QRS morphology and increased stim-to-QRS time were observed. HBP was confirmed when paced and native QRS were identical in morphology. RF energy was applied at the site of HBP capture until AV block was observed.
Results:
Baseline characteristics of patients in each arm were not significantly different. Compared with the standard approach, HBP was associated with trends toward lower RF applications (3 vs. 2, P = 0.16) and shorter mean RF time (208 seconds vs. 128 seconds, P = 0.19).
Conclusion:
HBP is an effective technique to identify optimal ablation sites during AVJ ablation and may shorten procedure time. HBP can be used to identify the AV node during AF without recording the His potential. Future studies with larger sample size are needed to better characterize the utility of this technique.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias VI: Management of Dysrhythmias