Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

596
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over...
596
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

14.9K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
14.9K
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

12.0K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
12.0K
Atomic Force Microscopy01:08

Atomic Force Microscopy

4.6K
Atomic force microscopy (AFM) is a type of scanning probe microscopy that can analyze topographic details of various specimens like ceramics, glass, polymers, and biological samples. AFM offers over 1000 times more resolution than the optical imaging system. Images generated from AFM are three-dimensional surface profiles, offering an advantage over the flat, two-dimensional images from other imaging techniques.
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
4.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Microblasting Wound Dressings Mechanically Disrupt Polymicrobial Biofilms to Enhance Healing in Treatment-Resistant Wounds.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Surface versus Nanocatalyst-Induced Matrix Bubbles Govern Temperature-Dependent Biofilm Removal.

ACS applied materials & interfaces·2026
Same author

Real-time, high-resolution metabolic characterization of live bacteria using label-free optical metabolic imaging.

NPJ biofilms and microbiomes·2026
Same author

Clinical trial assessing the use of optical coherence tomography in decision making for children presenting with acute otitis media.

International journal of pediatric otorhinolaryngology·2026
Same author

On the importance of simultaneous label-free multimodal nonlinear optical imaging for biomedical applications.

APL photonics·2025
Same author

Consensus guidelines for cellular label-free optical metabolic imaging: ensuring accuracy and reproducibility in metabolic profiling.

Journal of biomedical optics·2025
Same journal

Generalizable framework for multi-site bone density prediction using non-dominant wrist optical biomarkers.

Biomedical optics express·2026
Same journal

Erratum: Review of dynamic optical coherence tomography for intracellular motility [Invited]: errata.

Biomedical optics express·2026
Same journal

Digital-micromirror-device-based illumination strategies for background suppression in single-molecule localization microscopy.

Biomedical optics express·2026
Same journal

Synergistic combination of convective self-assembly and hollow core fiber for sensitive SERS detection of glucose molecules.

Biomedical optics express·2026
Same journal

Multimodal diagnostic network integrating infrared and mass spectra for lung cancer.

Biomedical optics express·2026
Same journal

Multimodal Optical Biosensing for Precision Medicine and Healthcare: Introduction to the feature issue.

Biomedical optics express·2026
See all related articles

Related Experiment Video

Updated: Mar 8, 2026

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

9.9K

Low-cost hand-held probe for depth-resolved low-coherence interferometry.

Paritosh Pande1, Ryan L Shelton1, Guillermo L Monroy2

  • 1Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.

Biomedical Optics Express
|January 20, 2017
PubMed
Summary
This summary is machine-generated.

We developed a low-cost, hand-held linear optical coherence tomography (Linear OCT) system for medical imaging. This simpler alternative to conventional OCT offers a cost-effective solution for specific applications.

Keywords:
(110.3175) Interferometric imaging(170.0110) Imaging systems(170.4500) Optical coherence tomography

More Related Videos

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
10:28

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

Published on: July 5, 2016

10.8K
Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
09:56

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time

Published on: November 4, 2014

11.3K

Related Experiment Videos

Last Updated: Mar 8, 2026

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

9.9K
Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
10:28

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

Published on: July 5, 2016

10.8K
Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
09:56

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time

Published on: November 4, 2014

11.3K

Area of Science:

  • Biomedical Optics
  • Medical Imaging Technology

Background:

  • Optical Coherence Tomography (OCT) is a powerful imaging technique.
  • Conventional OCT systems can be complex and expensive.
  • Linear OCT offers a simpler alternative.

Purpose of the Study:

  • To develop a low-cost, hand-held Linear OCT imaging system.
  • To validate the performance of the developed system.
  • To assess its suitability for specific imaging applications.

Main Methods:

  • Development of a bench-top Linear OCT system.
  • Validation of axial resolution, SNR, and sensitivity roll-off.
  • Creation of two hand-held probe implementations.
  • Comparison with a state-of-the-art Fourier-domain LCI system.

Main Results:

  • The bench-top system achieved 5.2 μm axial resolution, 80 dB SNR, and 3.7 dB sensitivity roll-off over 0.15 mm.
  • Hand-held probes were developed for contact and in vivo imaging.
  • Performance was comparable to research-grade systems for certain applications.

Conclusions:

  • The developed low-cost, hand-held Linear OCT system is a viable option.
  • It offers a trade-off between imaging depth/SNR and cost/simplicity.