Related Experiment Video
Updated: Mar 8, 2026

Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure
Rossano Girometti1, Martina Zanotel2, Viviana Londero1
1Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, University of Udine, Azienda Ospedaliero-Universitaria, 'S. Maria della Misericordia', Udine, Italy.
Objectives:
To evaluate the agreement between automated breast volume scanner (ABVS) and conventional ultrasound (US) as a second-look (SL) tool for assessing additional findings found on MRI.
Methods:
Over a 7-month period, we prospectively assigned to SL-US and SL-ABVS all patients undergoing 1.5 T breast MRI in whom additional findings were found. Five experienced breast radiologists independently interpreted SL-US and SL-ABVS in blinded sessions to evaluate the detection rate of MRI findings and assign them to BI-RADS categories. We calculated the agreement between the two methods in assessing MRI findings as significant (BI-RADS 3-5) versus not significant (BI-RADS 1-2), as well as their cancer detection rate.
Results:
In a population of 131 patients, SL-ABVS and SL-US showed a comparable detection rate of MRI findings (69.3 vs. 71.5%) (p > 0.05; McNemar test), with an almost perfect agreement in assessing them as significant or not (k = 0.94). This translated into a comparably high cancer detection rate (83.8% for SL-ABVS vs. 87.0% for SL-US). Only 1/31 cancers was missed by SL-ABVS.
Conclusions:
SL-ABVS and SL-US are nearly equivalent in assessing the significance of MRI findings, leading to a comparable cancer detection rate. SL-ABVS has the potential to replace SL-US in the SL scenario.
Key Points:
• SL-ABVS shows almost perfect agreement with SL-US in assessing MRI findings. • SL-ABVS shows a comparably high cancer detection rate with respect to SL-US. • SL-ABVS has the potential to replace SL-US in evaluating additional MRI findings.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies II: Ultrasonography
Imaging Studies IV: Magnetic Resonance Imaging
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Ultrasonography
During an ultrasonography procedure, a handheld device called...