Theoretical and experimental comparison of one dimensional versus on-line comprehensive two dimensional liquid
Morgan Sarrut1, Florent Rouvière1, Sabine Heinisch1
1Université de Lyon, Institut des Sciences Analytiques, UMR 5280, CNRS, Université Lyon 1, ENS Lyon, 5 rue de la Doua, 69100 Villeurbanne, France.
Abstract:
This study was devoted to the search for conditions leading to highly efficient sub-hour separations of complex peptide samples with the objective of coupling to mass spectrometry. In this context, conditions for one dimensional reversed phase liquid chromatography (1D-RPLC) were optimized on the basis of a kinetic approach while conditions for on-line comprehensive two-dimensional liquid chromatography using reversed phase in both dimensions (on-line RPLCxRPLC) were optimized on the basis of a Pareto-optimal approach. Maximizing the peak capacity while minimizing the dilution factor for different analysis times (down to 5min) were the two objectives under consideration. For gradient times between 5 and 60min, 15cm was found to be the best column length in RPLC with sub-2μm particles under 800bar as system pressure. In RPLCxRPLC, for less than one hour as first dimension gradient time, the sampling rate was found to be a key parameter in addition to conventional parameters including column dimension, particle size, flow-rate and gradient conditions in both dimensions. It was shown that the optimum sampling rate was as low as one fraction per peak for very short gradient times (i.e. below 10min). The quality descriptors obtained under optimized RPLCxRPLC conditions were compared to those obtained under optimized RPLC conditions. Our experimental results for peptides, obtained with state of the art instrumentation, showed that RPLCxRPLC could outperform 1D-RPLC for gradient times longer than 5min. In 60min, the same peak intensity (same dilution) was observed with both techniques but with a 3-fold lower injected amount in RPLCxRPLC. A significant increase of the signal-to-noise ratio mainly due to a strong noise reduction was observed in RPLCxRPLC-MS compared to the one in 1D-RPLC-MS making RPLCxRPLC-MS a promising technique for peptide identification in complex matrices.
More Related Videos
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
11:17A Simple Fractionated Extraction Method for the Comprehensive Analysis of Metabolites, Lipids, and Proteins from a Single Sample
Published on: June 1, 2017
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Principles Of Column Chromatography