Impact of a detector dead time in phase-resolved Doppler analysis using spectral domain optical coherence tomography
Abstract:
For any oblique sample movement containing a transverse velocity component, the commonly used linear relationship between the phase shift and the axial velocity component is erroneous for spectrometer-based optical coherence tomography (spectral domain OCT, SD-OCT). We recently proposed a new Doppler model that assumes a continuous integration of the photocurrent. In this research, we extend the model for detectors with a shutter control by taking detector dead time into account. We present the new relation between phase shift and oblique sample displacement as well as the correlation of the phases of consecutive depth scans, in dependency on the detector dead times ranging from 5% to 90%, as numerically calculated universal contour plots, which are valid for any center wavelength and sample beam size. We found that detector dead time is recommended, especially for oblique sample motion. The reason for this recommendation is the achieved linear relation between the phase shift and the axial velocity component in the velocity range relevant for in vivo measurements, despite the signal damping due to shorter exposure time of the line detector. The theoretical Doppler model is verified using a 1% Intralipid flow phantom model. Because of the results of this research, we believe future measurements in Doppler SD-OCT can be more simple and more accurate by setting a shutter control for the line detector used.
Related Concept Videos
Doppler Effect - II
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Doppler Effect - I
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...