Procedure for the Selection and Validation of a Calibration Model II-Theoretical Basis
Brigitte Desharnais1,2, Félix Camirand-Lemyre3, Pascal Mireault4
1Laboratoire de sciences judiciaires et de médecine légale, Department of Toxicology, 1701 rue Parthenais, Montréal, Québec, Canada H2K 3S7.
Abstract:
In the first part of this paper (I-Description and application), an automated, stepwise and analyst-independent process for the selection and validation of calibration models was put forward and applied to two model analytes. This second part presents the mathematical reasoning and experimental work underlying the selection of the different components of this procedure. Different replicate analysis designs (intra/inter-day and intra/inter-extraction) were tested and their impact on test results was evaluated. For most methods, the use of intra-day/intra-extraction measurement replicates is recommended due to its decreased variability. This process should be repeated three times during the validation process in order to assess the time stability of the underlying model. Strategies for identification of heteroscedasticity and their potential weaknesses were examined and a unilateral F-test using the lower limit of quantification and upper limit of quantification replicates was chosen. Three different options for model selection were examined and tested: ANOVA lack-of-fit (LOF), partial F-test and significance of the second-order term. Examination of mathematical assumptions for each test and LC-MS-MS experimental results lead to selection of the partial F-test as being the most suitable. The advantages and drawbacks of ANOVA-LOF, examination of the standardized residuals graph and residuals normality testing (Kolmogorov-Smirnov or Cramer-Von Mises) for validation of the calibration model were examined with the last option proving the best in light of its robustness and accuracy. Choosing the correct calibration model improves QC accuracy, and simulations have shown that this automated scheme has a much better performance than a more traditional method of fitting with increasingly complex models until QC accuracies pass below a threshold.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Calibration Curves: Correlation Coefficient
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...