Related Experiment Video
Updated: Mar 7, 2026

Assessment and Communication for People with Disorders of Consciousness
Published on: August 1, 2017
Signal-independent noise in intracortical brain-computer interfaces causes movement time properties inconsistent with
Francis R Willett1,2, Brian A Murphy1,2, William D Memberg1,2
1Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States of America.
Objective:
Do movements made with an intracortical BCI (iBCI) have the same movement time properties as able-bodied movements? Able-bodied movement times typically obey Fitts' law: [Formula: see text] (where MT is movement time, D is target distance, R is target radius, and [Formula: see text] are parameters). Fitts' law expresses two properties of natural movement that would be ideal for iBCIs to restore: (1) that movement times are insensitive to the absolute scale of the task (since movement time depends only on the ratio [Formula: see text]) and (2) that movements have a large dynamic range of accuracy (since movement time is logarithmically proportional to [Formula: see text]).
Approach:
Two participants in the BrainGate2 pilot clinical trial made cortically controlled cursor movements with a linear velocity decoder and acquired targets by dwelling on them. We investigated whether the movement times were well described by Fitts' law.
Main Results:
We found that movement times were better described by the equation [Formula: see text], which captures how movement time increases sharply as the target radius becomes smaller, independently of distance. In contrast to able-bodied movements, the iBCI movements we studied had a low dynamic range of accuracy (absence of logarithmic proportionality) and were sensitive to the absolute scale of the task (small targets had long movement times regardless of the [Formula: see text] ratio). We argue that this relationship emerges due to noise in the decoder output whose magnitude is largely independent of the user's motor command (signal-independent noise). Signal-independent noise creates a baseline level of variability that cannot be decreased by trying to move slowly or hold still, making targets below a certain size very hard to acquire with a standard decoder.
Significance:
The results give new insight into how iBCI movements currently differ from able-bodied movements and suggest that restoring a Fitts' law-like relationship to iBCI movements may require non-linear decoding strategies.
More Related Videos
11:25Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding
Published on: July 26, 2013
06:37Electroencephalography Network Indices as Biomarkers of Upper Limb Impairment in Chronic Stroke
Published on: July 14, 2023