A Standard Reference Material for Calibration of the Cup Furnace Smoke Toxicity Method for Assessing the Acute

Barbara C Levin1, Maya Paabo1, Susannah B Schiller1

  • 1National Institute of Standards and Technology, Gaithersburg, MD 20899.

Related Concept Videos

Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
1.7K
Toxicity Testing in Animals01:23

Toxicity Testing in Animals

Toxicity tests in animals are grounded on two main assumptions: first, the effects observed in laboratory animals can be extrapolated to humans, especially when adjusted for body surface area; second, high-dose exposure in animals is essential to identify potential human hazards from lower doses. This is based on the quantal dose-response concept, which faces the challenge of extrapolating results from relatively few test animals to much larger human populations. For example, a 0.01% incidence...
79
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
1.1K
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...