Related Experiment Video
Updated: Mar 7, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Precise simultaneous quantification of methadone and cocaine in rat serum and brain tissue samples following their
David S Nakhla1, Lobna A Hussein2, N Magdy2
1Department of Pharmaceutical Sciences, University of Maryland, School of Pharmacy, Baltimore, MD, United States; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Misr International University, Cairo, Egypt.
Abstract:
A sensitive high-performance liquid chromatography (HPLC) assay with dual UV detection has been developed and validated for the simultaneous quantification of methadone and cocaine in rat serum and brain tissue samples. Liquid-liquid extraction using hexanes was applied for samples extraction with Levo-Tetrahydropalmatine (L-THP) as the internal standard. Chromatographic separation of the analytes was achieved on a reversed-phase Waters Symmetry® C18 column (150mm×4.6mm, 5μm). A gradient elution was employed with a mobile phase consisting of 5mM potassium phosphate containing 0.1% triethylamine (pH=6.5) (A) and acetonitrile (B) with a flow rate of 1mL/min. UV detection was employed at 215nm and 235nm for the determination of methadone and cocaine, respectively. The calibration curves were linear over the range of 0.05-10μg/mL for both methadone and cocaine. The assay was validated according to FDA guidelines for bioanalytical method validation and results were satisfactory and met FDA criteria. Inter-day accuracy values of serum and brain samples ranged from 96.97 to 105.59% while intra-day accuracy values ranged from 91.49 to 111.92%. Stability assays showed that both methadone and cocaine were stable during sample storage, preparation, and analytical procedures. The method was successfully used to analyze biological samples obtained from a drug- drug interaction pharmacokinetics (PK) study conducted in rats to investigate the effect of methadone on cocaine PK. Our method not only can be used for bioanalysis of samples obtained from rats but also can potentially be applied to human biological serum samples to monitor compliance to methadone maintenance therapy (MMT) and to detect possible cocaine-methadone co-abuse.
More Related Videos
11:26Assessment of Dopaminergic Homeostasis in Mice by Use of High-performance Liquid Chromatography Analysis and Synaptosomal Dopamine Uptake
Published on: September 21, 2017
09:54Combining Laser Capture Microdissection and Microfluidic qPCR to Analyze Transcriptional Profiles of Single Cells: A Systems Biology Approach to Opioid Dependence
Published on: March 8, 2020