Related Experiment Video
Updated: Aug 2, 2026

Thin-layer Chromatographic (TLC) Separations and Bioassays of Plant Extracts to Identify Antimicrobial Compounds
Published on: March 28, 2014
Direct extraction of tetracyclines from bovine milk using restricted access carbon nanotubes in a column switching
Henrique Dipe de Faria1, Mariana Azevedo Rosa1, Alberto Thalison Silveira1
1Laboratory of Toxicant and Drug Analyses, Gabriel Monteiro da Silva St. 700, Federal University of Alfenas - Unifal-MG, 37130-000, Alfenas, MG, Brazil.
Abstract:
This paper describes, for the first time, the use of restricted access carbon nanotubes (RACNTs) in the analysis of tetracyclines from milk samples, in a multidimensional liquid chromatographic system. Milk samples were initially acidified and centrifuged, and then the supernatant was directly analyzed in a column switching system in backflush configuration employing an extraction column of RACNTs. The sorbent was able to exclude all the remained proteins in less than 2.0min. The method was linear from 50 to 200μgL-1 and the coefficients of determination (r2) were 0.997, 0.992, 0.994 and 0.998 for oxytetracycline (OXI), tetracycline (TC), chlortetracycline (CTC) and doxycycline (DOX), respectively. The analytical range included the maximum residue limits established by the regulatory agency.
Related Concept Videos
Principles Of Column Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...