Related Experiment Video
Updated: Mar 7, 2026

Monitoring Protein Adsorption with Solid-state Nanopores
Published on: December 2, 2011
A Review of Techniques to Measure Protein Sorption to Soft Contact Lenses
Brad Hall1, James A Forrest, Lyndon Jones
1Centre for Contact Lens Research (B.H., J.A.F., L.J.), School of Optometry and Vision Science University of Waterloo, Waterloo, ON, Canada; Department of Physics and Astronomy (J.A.F.), University of Waterloo, ON, Canada; Sengi Data (B.H.), Cambridge, ON, Canada; and Perimeter Institute for Theoretical Physics (J.A.F.), Waterloo, ON, Canada.
Purpose:
To compare and critically evaluate a variety of techniques to measure the quantity and biological activity of protein sorption to contact lenses over short time periods.
Methods:
A literature review was undertaken investigating the major techniques to measure protein sorption to soft contact lens materials, with specific reference to measuring protein directly on lenses using in situ, ex situ, protein structural, and biological activity techniques.
Results:
The use of in situ techniques to measure protein quantity provides excellent sensitivity, but many are not directly applicable to contact lenses. Many ex situ techniques struggle to measure all sorbed proteins, and these measurements can have significant signal interference from the lens materials themselves. Techniques measuring the secondary and tertiary structures of sorbed proteins have exhibited only limited success.
Conclusions:
There are a wide variety of techniques to measure both the amount of protein and the biological activity of protein sorbed to soft contact lens materials. To measure the mass of protein sorbed to soft contact lenses (not just thin films) over short time periods, the method of choice should be I radiolabeling. This technique is sensitive enough to measure small amounts of deposited protein, provided steps are taken to limit and measure any interaction of the iodine tracer with the materials. To measure the protein activity over short time periods, the method of choice should be to measure the biological function of sorbed proteins. This may require new methods or adaptations of existing ones.
More Related Videos
09:43Study of Short Peptide Adsorption on Solution Dispersed Inorganic Nanoparticles Using Depletion Method
Published on: April 11, 2020
13:22Adhesion Frequency Assay for In Situ Kinetics Analysis of Cross-Junctional Molecular Interactions at the Cell-Cell Interface
Published on: November 2, 2011