Related Experiment Video
Updated: Mar 7, 2026

Data Acquisition and Analysis In Brainstem Evoked Response Audiometry In Mice
Published on: May 10, 2019
ROC surface assessment of the ANB angle and Wits appraisal's diagnostic performance with a statistically derived
Hans L L Wellens1, Ellen A BeGole2, Annemarie M Kuijpers-Jagtman1
1Department of Orthodontics and Craniofacial Biology, Radboud University Nijmegen Medical Centre Nijmegen, The Netherlands.
Objective:
To assess the ANB angle's and Wits appraisal's diagnostic performance using an extended version of Receiver Operating Curve (ROC) analysis, which renders ROC surfaces. These were calculated for both the conventional and normalized cephalometric tests (calculated by exchanging the patient's reference landmarks with those of the Procrustes superimposed sample mean shape).The required 'gold standard' was derived statistically, by applying generalized Procrustes superimposition (GPS) and principal component analysis (PCA) to the digitized landmarks, and ordering patients based upon their PC2 scores.
Methods:
Digitized landmarks of 200 lateral cephalograms (107 males, mean age: 12.8 years, SD: 2.2, 93 females, mean age: 13.2 years, SD: 1.7) were subjected to GPS and PCA. Upon calculating the conventional and normalized ANB and Wits values, ROC surfaces were constructed by varying not just the cephalometric test's cut-off value within each ROC curve, but also the gold standard cut-off value over different ROC curves in 220 steps between -2 and 2 standard deviations along PC2. The volume under the resulting ROC surfaces (VUS) served as a measure of overall diagnostic performance. The statistical significance of the volume differences was determined using permutation tests (1000 rounds, with replacement).
Results:
The diagnostic performance of the conventional ANB and Wits was remarkably similar for both Class I/II (81.1 and 80.75% VUS, respectively, P > 0.05). Normalizing the measurements improved all VUS highly significantly (91 and 87.2 per cent, respectively, P < 0.001).
Conclusion:
The conventional ANB and Wits do not differ in their diagnostic performance. Normalizing the measurements does seem to have some merit.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
09:00Author Spotlight: Validation of SICOLE-R for Assessing Cognitive and Reading Skills in Spanish-Speaking Children and Its Role in Personalized Education
Published on: August 16, 2024
Related Concept Videos
Receiver Operating Characteristic Plot
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Angle of Twist: Problem Solving
Kendall's Coefficient of Concordance
McNemar's Test