Related Experiment Video
Updated: Mar 7, 2026

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Increasing the linear dynamic range in LC-MS: is it valid to use a less abundant isotopologue?
Stephen Trobbiani1, Peter Stockham1,2, Timothy Scott1,2
1Forensic Science SA, GPO Box 2790, Adelaide, South Australia, 5000, Australia.
Abstract:
Liquid chromatography-mass spectrometry (LC-MS) has quickly become the analytical method of choice in forensic toxicology laboratories due to its ability to detect a very wide range of compounds in a single analysis. One of the major limitations of LC-MS however, is a relatively limited linear dynamic range for quantitation. A new approach to combating this problem is to use the [+1 M + H]+ isotope mass peak for quantitation, thereby reducing saturation at the detector and extending the linear range. This is particularly useful in full-scan applications, such as quadrupole-time-of-flight (QTOF) mass spectrometry, where the isotopic mass peaks are acquired as a matter of course. Due to the variation in abundance of naturally occurring isotopes for common elements, especially 13 C, this technique has the potential to lead to additional quantitative error. Through a review of published isotope ratio mass spectrometry data, we have assessed this potential for error and found that it is likely to be less than 2% and unlikely to be more than 4%, although this may not apply to compounds containing high numbers of nitrogen or sulphur atoms. This additional potential error must be considered before using this technique as it may not be appropriate for all applications. We have deemed it fit for purpose for our application and demonstrate the applicability of this technique to a quantitative LC-TOF method. © 2017 Commonwealth of Australia. Drug Testing and Analysis © 2017 John Wiley & Sons, Ltd.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Isotope Effect
High-Resolution Mass Spectrometry (HRMS)
Mass Analyzers: Overview
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...